3M Novec7100 Electronic fluorination solution Cas 163702-08-7
Introduction
3M™ Novec™ 7100 Engineered Fluid, methoxy-nonaful orobutane (C4F9OCH3), is a clear, colorless and
low-odor ful id intended to replace ozone-depleting substances (ODSs) and compounds with high global
warming potential (GWP) in many applications. Its physical properties are compared with several other ODS
replacement ful id candidates in Table 1.
This proprietary ful id has zero ozone depletion potential and other favorable environmental properties (see
Table 2). It has one of the best toxicological profiles of CFC replacement materials, with a time-weighted
average exposure guideline of 750 ppm (eight hour average).
The high boiling point and low surface tension of Novec 7100 ful id make it ideal for use in vapor degreasing
applications as a neat (pure), azeotropic component or co-solvent parts cleaner. In addition, its chemical and
thermal stability, non-fal mmability and low toxicity make it useful for many other industrial and specialty
solvent applications (see below).
Applications
• Cleaning and rinsing agent |
• Lubricant carrier |
• Spray contact cleaner |
Heavy-duty cleaning (co-solvent) |
Fluorocarbons |
• CFC, HCFC, HFC and PFC |
– heavy oils, greases, fluxes |
Hydrocarbons |
replacement |
Medium-duty cleaning |
Silicones |
• Dielectric test media |
(azeotrope)– oils, greases, waxes |
• Spot-free water drying agent |
• Dielectric test media |
Light-duty cleaning (neat)– |
(with surfactants added) |
• Heat transfer |
particulates, fluorolubes, light |
• Specialty solvents, dispersion |
See “3M™ Novec™ 7100 |
oils, fluoropolymers |
media, reaction media |
Engineered Fluid for Heat
Transfer” Application Information |
Material Description
Not for specifci ation
purposes. All values
@ 25°C unless
otherwise specifei d.
|
Ingredients |
3M™ Novec™ 7100 Engineered Fluid |
Methoxy-nonafluorobutane1 |
99.5% minimum |
Non-volatile residue (NVR) |
2.0 ppm maximum |
Appearance |
Clear, colorless |
1Novec 7100 fluid (C4F9OCH3) consists of two inseparable isomers with essentially identical properties. These are (CF3)2CFCF2OCH3
(CAS No. 163702-08-7) and CF3CF2CF2CF2OCH3 (CAS No. 163702-07-6).
Typical Physical Properties
Data compiled
from published
information.
Not for specification
purposes. All values
@ 25°C unless
otherwise specified. |
Properties |
3M™ Novec™ 7100
Engineered Fluid
|
CFC-113 |
HCFC-141b |
HCFC-225 ca/cb1 |
HFC-4310mee |
Formula |
C4F9OCH3 |
C2Cl3F3 |
C2Cl2H3F |
C3Cl2HF5 |
C5H2F10 |
Molecular Weight |
250 |
187 |
117 |
203 |
252 |
Boiling Point (°C) |
61 |
48 |
32 |
54 |
54 |
Freeze Point (°C) |
-135 |
-35 |
-103 |
-131 |
-80 |
Liquid Density (g/ml) |
1.52 |
1.56 |
1.23 |
1.55 |
1.58 |
Surface Tension (dynes/cm) |
13.6 |
17.3 |
19.3 |
16.2 |
14.1 |
Solubility of Solvent in Water (ppmw) |
12 |
170 |
210 |
330 |
140 |
Solubility of Water in Solvent (ppmw) |
95 |
110 |
420 |
310 |
49 |
Vapor Pressure (mmHg) |
202 |
334 |
569 |
290 |
226 |
Environmental and Safety Properties
Properties |
3M™ Novec™ 7100
Engineered Fluid
|
CFC-113 |
HCFC-141b |
HCFC-225 ca/cb1 |
HFC-4310mee |
Ozone Depletion Potential–ODP1 |
0.00 |
0.80 |
0.10 |
0.03 |
0.00 |
Global Warming Potential2 |
320 |
6000 |
700 |
180/160 |
1700 |
Atmospheric Lifetime (years) |
4.1 |
85 |
9.2 |
2.1/6.2 |
17.1 |
Flash Point |
None |
None |
None |
None |
None |
Flammability Range in Air |
None |
None |
7.6-17.74 |
None |
None |
Exposure Guidelines (8 hr. time-weighted average) |
750 |
1000 |
500 |
50 |
200 |
Exposure Ceiling (ppm) |
None |
None |
None |
None |
400 |
Acute Toxicity (4 hr. LC50 [Rat]) |
>100,000 |
55,000 |
62,000 |
37,000 |
11,000 |
1HCFC-225 ca/cb ratio is 45/55 2 CFC-11 = 1.0 3 GWP–100 year Integration Time Horizon (ITH) 4 Vol % by ASTM E681-94 @ 100°C
Regulatory Status
3M™ Novec™ 7100 Engineered Fluid has been accepted for commercial use by regulatory agencies in the
United States, Europe, Canada, Australia, Japan, Korea and the Philippines. The components of Novec 7100
fluid have been nominated to China’s draft chemical inventory.
Novec 7100 fluid has been approved under the Significant New Alternatives Policy (SNAP) of the U.S. EPA. In
addition, Novec 7100 fluid has been excluded by the U.S. EPA from the definition of a VOC on the basis that
this compound has negligible contribution to tropospheric ozone formation. The components of Novec 7100
fluid are not on any regulated lists.
Contact your local 3M representative regarding the regulatory status of Novec 7100 fluid in other countries.
Toxicity Profile
The toxicological testing completed on Novec 7100 fluid shows the overall toxicity is low. The material
is practically non-irritating to the eyes, minimally irritating to the skin and is not a mutagen or cardiac
sensitizer. It is rated “practically non-toxic” through inhalation. A 90-day inhalation study has helped establish
a recommended exposure guideline of 750 ppm for an eight-hour average worker exposure per day. This
exposure guideline was established by the American Industrial Hygiene Association.
Properties |
3M™ Novec™ 7100 Engineered Fluid |
Acute Lethal Inhalation Concentration |
>100,000 ppm (4 hour) |
Oral |
Practically non-toxic (>5g/kg) |
Eye Irritation |
Practically non-irritating |
Skin Irritation |
Minimally irritating |
Skin Sensitization |
Not a skin sensitizer |
Inhalation (90 day study) |
750 ppm exposure guideline Detailed results are available |
Developmental Toxicity |
Detailed results are available |
Mutagenicity |
Negative in the three assays conducted |
Cardiac Sensitization |
No signs of sensitization at exposures up to 100,000 ppm |
Ecotoxicity Testing |
Complete – very low aquatic toxicity |
Vapor Pressure and Density
The variation of vapor pressure and density with temperature for 3M™ Novec™ 7100 Engineered Fluid can be
calculated using the following formulas:
Vapor Pressure: ln P = 22.415 - 3641.9 [1/(t+273)]
Density: D = 1.5383 - 0.002269t
P =Vapor Pressure in Pascals
t =Temperature in °C
D =Density in g/ml
Materials Compatibility
Continuous Exposure
Novec 7100 fluid is compatible with most metals and hard polymers. Soft and elastomeric materials should be
limited to compounds that contain the least amount of extractable plasticizer. 3M technical service engineers
can suggest appropriate compounds and assist with material compatibility tests.
Non-Continuous Exposure
Short-term testing of Novec 7100 fluid demonstrates compatibility, after one hour exposure at boiling
temperature, with a wide range of metals, plastics and elastomers, similar to the performance of perfluorinated
liquids. Good short-term compatibility with particularly sensitive plastics such as polycarbonate and PMMA
indicates utility in cleaning of assemblies containing many composite materials.
As with most fluorinated liquids, Novec 7100 fluid will absorb into fluorinated plastics and elastomers over
longer exposures.
Short-Term Exposure Compatibility
Metals |
Plastics |
Elastomers |
Aluminum Molybdenum
Copper Tantalum
Carbon Steel Tungsten
302 Stainless Steel Cu/Be Alloy C172
Brass Mg Alloy AZ32B
|
Acrylic (PMMA) Epoxy
Polyethylene PET
Polypropylene Phenolic
Polycarbonate ABS
Polyester
|
Butyl Rubber
Polyethylene PET
Nitrile Rubber
EPDM
|
Exceptions: Some swelling of PTFE and Silicone Rubber. Some surface oxidation of copper during heat aging.
Safety and Handling
3M™ Novec™ 7100 Engineered Fluid is nonflammable and does not exhibit flammability characteristics under
normal operating and storage conditions. This fluid is highly resistant to thermal breakdown and hydrolysis in
storage and during use. Recommended handling procedures are provided in the pertinent Material Safety Data
Sheet which is available from your local 3M representative upon request.
Environmental Policy
3M will continue to recognize and exercise its responsibility to prevent pollution at the source wherever and
whenever possible; develop products that will have a minimal effect on the environment; conserve natural
resources through the use of reclamation and other appropriate methods; assure that its facilities and products
meet and sustain the regulations of all federal, state and local environmental agencies; assist, wherever
possible, governmental agencies and other official organizations engaged in environmental activities
Packaging and Availability
3M™ Novec™ 7100 Engineered Fluid may be ordered in the following container sizes:
• 55-gallon drum; 30-gallon drum; 5-gallon pail; 1-gallon pail
• 4-ounce samples for limited or preliminary test work are available
Recycle and Disposal Options
Used Fluid Return Program
3M offers a program for free pickup and return of used 3M specialty fluids in the U.S. A pre-negotiated
handling agreement between users and our authorized service provider offers users broad protection against
future liability for used 3M product. The fluid return program is covered by independent third-party financial
and environmental audits of treatment, storage and disposal facilities. Necessary documentation is provided. A
minimum of 30 gallons of used 3M specialty fluid is required for participation in this free program.
For additional information on the 3M Used Fluid Return Program, contact your local 3M representative or call
3M Customer Service at 800.810.8513.
Resources
3M™ Novec™ Engineered Fluids are supported by global sales, technical and customer service resources, with
technical service laboratories in the U.S., Europe, Japan, Latin America and Southeast Asia. Users benefit
from 3M’s broad technology base and continuing attention to product development, performance, safety and
environmental issues. For additional technical information on Novec 7100DL fluid in the United States or for
the name of a local authorized distributor, call 3M Electronics Markets Materials Division: 800 810 8513.